
Based on Official Syllabus Topics of Actual NACE NACE-CIP2-001 Exam
Free NACE-CIP2-001 Dumps are Available for Instant Access
NACE-CIP2-001 (Coating Inspector Level 2) Exam is a certification exam offered by the National Association of Corrosion Engineers (NACE) International. NACE-CIP2-001 exam is designed for professionals in the coating industry who wish to demonstrate their knowledge and experience in the inspection of coatings. As a Level 2 certification, it requires a greater level of knowledge and experience than the Level 1 certification.
The Coating Inspector Level 2 Exam is intended for individuals who have a minimum of two years of experience in the coating inspection field, including surface preparation, coatings application, and inspection techniques. NACE-CIP2-001 exam covers a variety of topics, including coating types and properties, surface preparation, coating application methods, inspection techniques, and safety procedures.
The NACE NACE-CIP2-001 exam covers a broad range of topics, including coating materials, surface preparation, application methods, and quality control procedures. It also includes sections on health and safety, environmental regulations, and project management. The questions are designed to evaluate the candidate's ability to identify and resolve issues related to coating systems, including defects, surface contaminants, and compatibility issues with existing substrates.
NEW QUESTION # 50
Coating Surveys are legally required:
- A. On water tanks and potable water pipelines
- B. On high pressure gas lines and fireproofed structures
- C. On commercial marine vessels and offshore platforms
- D. On food and beverage vessels and can linings
Answer: C
NEW QUESTION # 51
An Inspection and Test Plan is required when:
- A. When the Inspector requests one
- B. When the Owner specifies one
- C. When the Coating Applicator requests one
- D. It is always required
Answer: D
NEW QUESTION # 52
You can use magnifiers to examine all of the following EXCEPT
- A. Surface profile
- B. Mill scale
- C. Blisters
- D. Surface cleanliness
Answer: D
NEW QUESTION # 53
When conducting inspections the Inspector should follow which standards:
- A. The specified standards
- B. Australian standards in Australia
- C. NACE and SSPC standards in North America
- D. ISO standards in Europe and Asia
Answer: A
NEW QUESTION # 54
WJ-1 is always performed using UHWJ at pressures above 210 MPa (30,000 PSI)
- A. True
- B. False
Answer: A
NEW QUESTION # 55
You are the NACY Coating Inspector on a tank lining project where desiccant dehumidification is being used. Since the first shift of abrasive blasting your readings have indicated relative humidity below 40%; however on the second shift of coating application your readings are indicting 80%.
Your FIRST preferred course of action is to:
- A. Document the readings at the end of the shift
- B. Check to See if the dehumidification equipment is operating correctly
- C. Call your supervisor
- D. Advise the coating applicator supervisor of your readings
Answer: D
NEW QUESTION # 56
All of these are advantages of using repair patches EXCEPT
- A. inert to common acids, alkalis, and solvents.
- B. barrier to moisture and corrosion.
- C. excellent abrasion resistance.
- D. special tools or equipment are required.
Answer: D
NEW QUESTION # 57
When a coating is expected to be exposed to temperatures above 93C (200 F) the best choice would be:
- A. Inorganic Coatings
- B. Polyurea
- C. Organic coatings
- D. Latex
Answer: A
NEW QUESTION # 58
Steel shot grit contaminated with oil or grease used in a cetrifugal blast cleaning should be
- A. disposed of properly.
- B. washed with clean potable water prior to Use.
- C. mixed with uncontaminated abrasive
- D. run through the air wash separator.
Answer: A
NEW QUESTION # 59
The most likely area of failure on a buried external pipeline coating is the:
- A. Ground bed
- B. Areas exposed to Ultra Violet light
- C. Field joint coating
- D. Mainline coating
Answer: C
NEW QUESTION # 60
The best choice of instrument for holiday testing of thick film concrete coatings is:
- A. High Voltage DC Pulse Type
- B. High Voltage AC
- C. High Voltage DC Constant Current
- D. Low Voltage Sponge Type
Answer: C
NEW QUESTION # 61
When performing a hardness test on a coating which has elastic properties the inspector is likely to likely to observe:
- A. Cold flow or creep
- B. A very high reading
- C. A very low reading
- D. No difference from any other coating
Answer: A
NEW QUESTION # 62
You are the NACE Level 2 inspector reviewing the documentation from a NACE Level 1 you notice significant documentation errors.
Your FIRST preferred course of action is to:
- A. Have the Level 1 Inspector correct the errors and set up remedial training to improve the quality of documentation
- B. Correct the errors yourself and suggest the Level 1 inspector be replaced
- C. Correct the errors yourself and advise your supervisor that the Level 1 Inspector is incompetent
- D. Correct the errors yourself and submit the reports without any further action
Answer: A
NEW QUESTION # 63
Inspector reports should always be copied to:
- A. Whomever the Owner identifies
- B. All parties involved in the project
- C. The Contractor and Owner
- D. The Owner only
Answer: A
NEW QUESTION # 64
On pipelines, which coating is identifiable by its distinct colors, usually light blue, green, or grey?
- A. Concrete
- B. Coal Tar Enamel
- C. Heat-shrink sleeves
- D. Liquid epoxies
Answer: D
NEW QUESTION # 65
Corrosion is the reverse process of
- A. flaking.
- B. steel manufacturing.
- C. hot dipping.
- D. galvanic deterioration.
Answer: B
NEW QUESTION # 66
The solvent sensitivity/solvent wipe test (ASTM D4752) is used to determine the cure of
- A. epoxies.
- B. inorganic zincs.
- C. urethanes.
- D. powder coatings.
Answer: B
NEW QUESTION # 67
Examples of non-ferrous metals include
Select All that Apply:
- A. mild steel.
- B. iron
- C. aluminum
- D. copper
Answer: C,D
NEW QUESTION # 68
Inspectors perform tests on linings that they may not perform on exterior coatings because
- A. linings protect the contents and the container.
- B. linings are more durable than coatings.
- C. coatings are expected to degrade over time.
- D. coatings are more durable than linings.
Answer: A
NEW QUESTION # 69
The Concrete Repair Institute's comparators can be used to assess:
- A. Compressive and tensile strength prior to coating
- B. Surface cleanliness prior to coating
- C. Contamination levels prior to coating
- D. Surface profile prior to coating
Answer: D
NEW QUESTION # 70
You should bulk store coatings containing isocyanates
- A. wherever it is convenient
- B. in a heated warehouse.
- C. in a well ventilated area separate from the work place.
- D. in a refrigerated warehouses
Answer: C
NEW QUESTION # 71
From a corrosion perspective, the main difference between Ferrous and Non-Ferrous Metals is:
- A. Cost
- B. Iron content
- C. Appearance
- D. Safety
Answer: B
NEW QUESTION # 72
When completing the Final Inspection report the Inspector should write the report using:
- A. Language that only technical experts would understand
- B. Language that only in the project would understand
- C. Language that another NACE Inspector would understand
- D. Language that the most would understand
Answer: D
NEW QUESTION # 73
......
The Most In-Demand NACE-CIP2-001 Pass Guaranteed Quiz : https://www.examcost.com/NACE-CIP2-001-practice-exam.html
View All NACE-CIP2-001 Actual Exam Questions Answers and Explanations for Free: https://drive.google.com/open?id=1DJ7DR3sa994yA6DknH_TMxfkmp3LtblN

