NEW QUESTION 163
A customer is experiencing read cache hit ratios well below 80 percent on an HPE Nimble HF40 array Data is constantly being ejected from the Nimble array's First In First Out cache What should you recommend?

  • A. Turn off deduplication on affected volumes
  • B. Enable InfoSlght's Al-based cache optimization setting
  • C. Upgrade the SSD bundle to add more capacity.
  • D. Turn on deduplication on affected volumes.

Answer: A

 

NEW QUESTION 164
You plan to install an HPE ProLiant DL360 Gen10 in an environment with an ambient temperature of 45 C (113 F).
Which additional option is required?

  • A. High Performance Fan Kit
  • B. 500W Flex Slot Platinum PS Kit
  • C. M.2 Solid State Enablement Kit
  • D. Gen10 Bezel Kit

Answer: A

 

NEW QUESTION 165
A customer purchased a Nimble HF20 a year ago They are experiencing an issue with a few of their VMware servers in the RTP Nimble date center and asked that you make a recommendation based on the data in infoSight.
What should you recommend'?

  • A. increase the datastore size for VMware-DS-Space-NoDeDup.
  • B. Add another datastore for the RTP Nimble Datacenter
  • C. Add cache to the array for the RTP Nimble Datacenter.
  • D. increase the cache size for VMware-DS-Space-NoDeDup

Answer: B

 

NEW QUESTION 166
Why is SNMPv2c considered to be insecure?

  • A. SNMPv2c only allows the signing of the message payload
  • B. SNMPv2c community strings are transmitted in clear text
  • C. SNMPv2c agents only encrypt WRITE messages.
  • D. SNMPv2c agents only accept GET requests which match their read-only community string

Answer: B

 

NEW QUESTION 167
What is the most important difference between an HPE ProLiant DL380 Gen10 server and an HPE ProLiant DL385 Gen10 server?

  • A. Disk Drives
  • B. Network Cards
  • C. Power Supplies
  • D. Processors

Answer: A

 

NEW QUESTION 168
Place the components on the left in the correct order on the right for the recommended power-up sequence.

Answer:

Explanation:

* SAN switches
* Tape libraries
* Disk storage
* Host servers

 

NEW QUESTION 169
Which protocol can be used to access a shared directory on a network-attached storage device?

  • A. SMB
  • B. SNMP
  • C. BGP
  • D. FCP

Answer: A

 

NEW QUESTION 170
Which web service uses baste CRUD operations performed on resources using HTTP Post, Get. Put. Delete, and Patch?

  • A. cURL
  • B. SOAP
  • C. REST
  • D. CORBA

Answer: B

 

NEW QUESTION 171
A customer wants to install an HPE Proliant server that has a single dual port 10Gb NIC.
Which NIC feature should you introduce to allow each 10Gb port to be seen as four individual adapters in the operating system?

  • A. NPAR
  • B. FCoE
  • C. RoCE
  • D. RDMA

Answer: A

 

NEW QUESTION 172
Match the Networking Product Family to the appropriate use case:

Answer:

Explanation:

 

NEW QUESTION 173
Refer to the exhibit.
Drag the correct protocols from the left to the appropriate area on the topology on the right.

Answer:

Explanation:

 

NEW QUESTION 174
Match the characteristic to the correct HPE ProLiant family.

Answer:

Explanation:

Explanation
ML,DL,DL,ML

 

NEW QUESTION 175
A customer is configuring their SAN.
Which types of data typically require block storage? (Choose two.)

  • A. Windows 2016 file server role
  • B. Microsoft Exchange
  • C. Bridgehead medical image archive
  • D. Oracle database
  • E. Enterprise Vault email archive

Answer: B,D

 

NEW QUESTION 176
HPE Support asks you to generate an SSD wear gauge report for local storage on an HPE DL360 Gen10 server running VMware.
Which procedure will ensure that the server will boot directly into a maintenance state so you can generate the requested report?

  • A. Use Always On functionality of Intelligent Provisioning
  • B. Changing the one-time boot option to Intelligent Provisioning in iLO web-based user interface
  • C. Changing the one-time boot option to Smart Storage Administrator in iLO web-based user interface
  • D. Click Boot to System Setup Utilities in iLO web-based user interface
  • E. Changing the one-time boot option to Intelligent Provisioning in HPE OneView

Answer: C

 

NEW QUESTION 177
Match each HPE solution to its corresponding technology usage.

Answer:

Explanation:

Explanation

 

NEW QUESTION 178
Refer to the exhibit.

A customer has two HPE ProLiant DL380 Gen10 servers running as an Oracle cluster. They are trying to reduce licensing costs and want to move to the best processor available from the list to minimize licensing costs while still providing a high level of performance for the Oracle database.
Which DL380 Gen10 processor would you recommend?

  • A. Intel Xeon-Platinum 8280
  • B. Intel Xeon-Platinum 8256
  • C. Intel Xeon-Platinum 8280M
  • D. Intel Xeon-Platinum 8253

Answer: B

 

NEW QUESTION 179
......