NEW QUESTION # 88
What is a consideration when populating DIMMs with different types of persistent memory in a Dell EMC PowerEdge 14G server?
- A. NVDIMMs cannot be mixed with RDlMMs
- B. NVDIMMs can be mixed only with LRDIMMs
- C. LRDIMMs can be mixed only with RDlMMs
- D. RDlMMs can be mixed only with NVDIMMs
Answer: B
NEW QUESTION # 89
A technician needs to add a device to SupportAssist Enterprise. Policy requires that no additional software be installed on the server OS.
In addition to Username and Password, what information is required to add the device?
- A. IP address or hostname for the iDRAC
- B. IP address or hostname for the server OS
- C. IP address for Dell TechDirect
- D. IP address fir OpenManage Server Administrator
Answer: A
NEW QUESTION # 90
A technician replaces the system board on a Dell EMC PowerEdge server.
Using the Easy Restore function, what can be restored to the new system board without the use of a USB device, Internet connection, or DVD?
- A. System Configuration settings, all licenses, Service tag, and Diagnostics
- B. BIOS configuration, RAID configuration, System Configuration settings, and iDRAC license
- C. RAID configuration, Firmware revision, iDRAC license, and Service tag
- D. Firmware revision, Service tag, Diagnostics, and BIOS configuration
Answer: A
NEW QUESTION # 91
A technician deletes the iDRAC Enterprise license on a R640 server.
Which license type is then enabled?
- A. iDRAC Express license
- B. iDRAC Enterprise license cannot be deleted
- C. iDRAC Basic license
- D. iDRAC will not have a license until a new one is installed
Answer: C
NEW QUESTION # 92
What color is used to designate a hot-swappable component?
- A. Amber
- B. Yellow
- C. Orange
- D. Blue
Answer: C
NEW QUESTION # 93
After a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster in the future, even at the expense of stowing users down.
How should the technician perform this task?
- A. Change the Rebuild Rate from me iDRAC GUI
- B. Change the Rebuild Rate in the System BIOS Settings
- C. Change the System Profile to Performance in the System BIOS Setting
- D. Change the System Profile 1o performance in the iDRAC GUI
Answer: A
NEW QUESTION # 94
A server has both processor sockets populated. An adapter card in the server is not functioning.
However, no errors are displayed. The technician reboots the server, enters the System Setup utility, and selects System BIOS.
What should the technician do before replacing the adapter card?
- A. Select Processor Settings
Verify that the slots associated with processor 1 are enabled - B. Select System Profile > Custom
Verify that the adapter slots for both processors are enabled - C. Select Integrated Device Settings > Slot Disablement
Verify that the adapter slot is enabled - D. Select Device Settings
Reset the adapter card to default settings
Answer: C
NEW QUESTION # 95
A technician needs to configure a server to PXE boot a server setup image with the BIOS in UEFI mode.
Which two steps should the technician perform to enable this function? (Choose two.)
- A. From System Setup Utility, choose Device Settings. Configure NIC for PXE.
- B. Boot to Ctrl+S and configure the NIC for PXE Device1.
- C. From the iDRAC web interface, select Network Settings, and enable PXE Device1.
- D. Navigate to Boot Options Settings and set PXE Device1 as first option.
- E. Navigate to Network Settings, PXE Device1 Settings, and configure IP.
Answer: B,D
NEW QUESTION # 96
A server is configured with a RAID 5 Virtual Disk across 5 hard disks and 1 spare disk. If a hard disk failure occurs within the RAID 5 virtual disk, the spare disk needs to be online as quickly as possible. It is acceptable for users to experience decreased performance during the rebuild procedure.
How should this requirement met?
- A. Increase Rebuild Rate
- B. Change cache to Write Through
- C. Enable Rebuild Priority
- D. Select Fast Rebuild
Answer: A
NEW QUESTION # 97
What does OBPAR allow on a PowerEdge MX750c?
- A. Boot a compute sled with reduced frequency.
- B. Run a compute sled with maximum performance.
- C. Boot a compute sled with only one CPU.
- D. Run a compute sled with memory overclocking.
Answer: A
NEW QUESTION # 98
The OS and iDRAC report 120 GB of RAM. The technician has very little time to troubleshoot the issue and cannot run diagnostics.
They are working with the following information:
- Memory mode is Optimizer
- 8x 16 GB DIMMs installed
- 2 CPUs
- No entries in the SEL in the iDRAC
- No errors in the OS
To troubleshoot this issue, what action should the technician take prior to monitoring POST for any resulting errors?
- A. Change memory mode to Advanced ECC
- B. Modify server profile for Performance
- C. Add an additional memory module
- D. Reseat all memory modules
Answer: D
NEW QUESTION # 99
A technician needs to remotely update the iDRAC with Lifecycle Controller firmware. They have downloaded the latest iDRAC firmware to the management station and connected to the iDRAC GUI.
What step is required to complete the update?
- A. Go to the Firmware Update page and upload the iDRAC firmware
- B. Boot the server into F10 to start the firmware update
- C. Boot into the OS via Virtual Console and execute the firmware
- D. Go to the Summary Page and reset the iDRAC
Answer: A
NEW QUESTION # 100
A technician has a server in production. The iDRAC SEL log indicates a possible issue with DIMMs A1 and A2. Firmware is up to date.
What is the most efficient way to troubleshoot this issue?
- A. Reseat DIMMs A1 and A2
- B. Swap DIMMs A1 and A2 to B1 and B2
- C. Swap DIMMs A1 and A2 to A3 and A4
- D. Swap DIMMs A1 and A2 to B1 and B3
Answer: A
NEW QUESTION # 101
A technician is troubleshooting a server with the following components:
Two CPUs
Memory installed in sockets A1, A2, A3, A4, A5, A6, B1, B2, B3, B4, B5 and B6 Expansion cards installed in all expansion slots
6x 1 TB drives configured as a RAID 6 virtual disk
The server has the following symptoms:
CPU2 has failed
Memory in slots B1, B2, B3, B4, B5 and B6 is not accessible
Some of the expansion cards have gone offline.
What should the technician do to resolve this issue?
- A. Replace the system board
- B. Replace the failing CPU, failing memory, and expansion cards
- C. Replace CPU2
- D. Reboot the server, access the Lifecycle and re-enable CPU2
Answer: C
NEW QUESTION # 102
A technician wants to obtain the highest overall efficiency from the power supplies.
Which options should the technician use?
- A. Power factor correction
Power supply hot spare - B. Power supply hot spare
A low-line power source - C. A low-line power source
Power factor correction - D. Power supply hot spare
Power supply redundancy
Answer: A
NEW QUESTION # 103
Which two iDRAC license editions support enabling the Lockdown Mode feature? (Select 2)
- A. iDRAC Express
- B. iDRAC Datacenter
- C. iDRAC Basic
- D. iDRAC Enterprise
Answer: B,D
NEW QUESTION # 104
SPECIAL INSTRUCTIONS
The remaining Part1 questions are associated with four case studies that describe various environments or settings. Each case study appears on its own display screen. Questions for each case study will appear on separate display screens. When displaying a question, you can easily review the related case study by clicking on the 'Review Case Study icon shown below:
Case Study 5 - Refer to the Exhibit.
Backing up data from a Dell EMC Isilon cluster exceeds the company's backup window. Because the company has a large amount of data with a continuous high growth rate, they want to change their backup strategy. The Gen 6 Isilon cluster consists of 24 nodes.
Their current backup strategy is an NDMP three-way backup performing weekly full backups to tape and incremental backups each night. The strategy uses Dell EMC Net Worker. The DMA uses Include paths to specify what data to backup. All data on the cluster must remain accessible.
The company's IT team is now looking for a new data protection strategy.
The company wants to:
- Minimize the backup window
- Increase the speed of data recovery
- Reduce the network traffic
- Reduce the overall growth of the backup datasets
The IT Team indicates that their currently backup hardware will be used in any solution.
Which solution meets their requirements?
- A. Configure the DMA to use IPv6 for better performance
- B. Increase the backup tape block size to 512 KB
- C. Change the backup strategy to token-based backups
- D. Implement an incremental forever backup strategy
Answer: D
NEW QUESTION # 105
A technician is updating firmware on a Windows Server using the Lifecycle Controller following a NIC replacement, but it fails to complete the update on the NIC despite successfully updating other components.
The update's read me confirms that the current version is too old to upgrade with the Lifecycle Controller and an alternative method must be used.
Which three update methods could the technician use to meet this requirement? (Choose three.)
- A. Launch Platform Update from OpenManage Server Administrator
- B. Use Update and Rollback within the iDRAC web GUI
- C. Create a bootable ISO file with Repository Manager
- D. Run a Dell Update Package (DUP) from the OS
- E. Launch Server Update Utility (SUU) from the OS
Answer: A,C,D
NEW QUESTION # 106
What happens when the Hardware Root of Trust fails to validate the BIOS?
- A. Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.
- B. The server continues running and logs a critical error in the system event log.
- C. The server shuts down and logs a critical error in the system event log.
- D. Boot Guard switches over to the backup BIOS and logs a warning in the system event log.
Answer: C
NEW QUESTION # 107
What is required to use the iSM Automatic System Recovery feature?
- A. OS watchdog timer disabled
- B. OS watchdog timer enabled
- C. Server Administrator installed
- D. Server Administrator not installed
Answer: A
NEW QUESTION # 108
A user has a fully configured PowerEdge R640 and an iSM installed on their Windows. 2016 operating system. They now want to install OMSA to enable them to have alerts sent out In-Band to a management console.
What does the user need to consider?
- A. OMSA can be installed on the same operating system with iSM without restrictions
- B. iSM must be disabled before OMSA can be installed
- C. iSM must be uninstalled before OMSA is installed
- D. OMSA can be installed on the same operating system with ISM. Provided both OMSA have iSM have the same firmware version revisions
Answer: A
NEW QUESTION # 109
......